Bookmark this page | Homepage | Casual look | Mobile version | 如有业务需要请点击QQ咨询如有业务需要请点击QQ咨询Skype ConsultingSkype Consulting
Member

Pharmachemist Ltd.&^

人民币


Products
  • No Category

Contact
  • Contact:pharmerchemistb
  • Phone:0551-62864156-606
Search
 

riends links
  • No link
Your current location:Home » Product supply » 808nm Diode Laser Hair Removal Machine,Freezing,Painless,Alternative IPL,2011-17
808nm Diode Laser Hair Removal Machine,Freezing,Painless,Alternative IPL,2011-17
Click image to view full size image
Product: Views:847808nm Diode Laser Hair Removal Machine,Freezing,Painless,Alternative IPL,2011-17 
Unit price: 3500.00元/BOX
MOQ: 1 BOX
Quantity: 10000 BOX
Delivery date: Since the payment date Days delivery
Valid until: Long-term effective
Last updated: 2017-02-07 17:05
  Inquiry
Details
Item specifics Condition: New: A brand-new, unused, unopened, undamaged item (including handmade items). See the sellers listing for full details.See all condition definitions- opens in a new window or tab... Read moreabout the condition Country/Region of Manufacture: Hong Kong
ta http-equiv="Content-Language" content="zh-cn"> 新建网页 1 ta http-equiv="Content-Language" content="zh-cn"> 新建网页 1 ta http-equiv="Content-Language" content="zh-cn"> 新建网页 1  

Product Name:

808 810nm Diode Laser Hair Removal Machine,Freezing, Painless Alternative IPL,OEM,2011-2017 New

Video  

Price:

Surprise Price and Amazing Product

Model No.:

1、808-HR-C(In stock)---------photo1

2、808-HR-E(In stock)---------photo2

3808-HR-F(In stock)---------photo3

4、808-HR-G(In stock)---------photo4

5、808-HR-H(In stock)---------photo5

4、808-HR-K(In stock)---------photo6

The default shipping DHL,the first interface,220V voltage

If you need 110V,Please give me a message

Keywords:

808 810nm Diode Laser Hair Removal Machine,Freezing, Painless Alternative IPL

Manufacturer:

OEM、ODM(Can design your interface,language translation)

Contact:

ebay message or Email

 Advantage:

Company Advantage:

1、We are professional laser diode manufacture with 10 years experience.

2、We are one of the few can encapsulate a variety of laser chip manufacture.

3、We provide OEM & ODM solutions from laser diodes to full system.

Product Advantage:

1、808nm Laser Hair Removal Machine is our own and design.Including handpiece,power,control panel,screen and watercooling system.

2、808nm laser hair removal has three main advantage:Freezing,Painless,Permanent hair removal.

3、Can according to your demand change interface, the company logo, language.

4、We are able to offer a variety of interface.

 

 

Specifications:

 

Parameter

Value(Default)

Note(Customize)

Wavelength

808nm+/-10nm

940nm optional

Pulse Width

25ms~400ms

 

Repetition Rate

1Hz~10Hz

 

Energy Fluence

0~120J/cm2

Up to 150J/cm2 optional

Beam Type

Collimated

Un-collimated optional

Skin Cooling

TEC + Sapphire

<5℃

Laser Window

15x15mm

 

Laser Cooling Liquid

Purified Water

Tap water allowed

Cooling Water Volume

3.0~3.5L

 

Handle Piece Flow Rate

3.5~4.0L/min

 

LCD Screen

8’ Touch LCD

6’~10.4’ optional

Pedal Switch

Support

 

Environment Temperature

5~30℃

 

Environment Moisture

<80%

 

Input VAC

220VAC / 50-60Hz

110VAC optional

Dimension

~4050x90cm

Optional

Weight

~40KG

Optional

Installation:

Do not power up the system before you checked this manual!

For air shipping regulations, the water inside of the machine must be cleaned. So the user needs to add water the first time when they receive the machine. Please take following steps to start the hair removal system.

1)       Open the package. Put the machine and handle piece in the right place for setup. Open the back panel by releasing the 8 screws with screw driver. Check following photo and you will find the tube which is shorted from bottom to the top of the water tank. Release the tube from the connector. Find a hard tube in the package accessories (outer diameter 8mm) and connect it to the top connector of the water tank. Use the plastic funnel to add water into the tank till the water level is close to 1cm to the top roof of the tank. If the water tank is not fully filled, there may be [ ERROR 6 ] alarm when you start the machine. The water can be regular purified water, or clean tap water without particles >0.1mm diameter. You may need 3~4 liters of water.

 

The water doesn’t need to be changed within at least 6 months if there is no alarm [ ERROR 6 ]. This alarm is designed with water level sensor. It means the water is not enough.

By the way, do not over-filled the water, or there may be some water leakage.

1)       Install the back panel with 8 screws.

2)       Check the handle piece if it is in good conditions. And also check the protection tube of the handle piece. Make sure it is not terribly bended or pressed. If the tube is terribly bended, this may cause water jam or not-enough water flow. This is not good for the laser cooling and may cause problem.

3)       Please confirm if your wall-plug is 200-240VAC. If it is 90-120VAC, please contact us to switch the voltage.

4)       Find a 10A 220-250V VAC plug wire (you may need an European Model for the wire), connect to the back panel.

5)       Turn on the air switch at the back panel.

6)       Check if the emergency button is pressed down. If pressed down, please release it. Or there will be [ ERROR 2 ].

7)       Use the key to start the system and you will enter the blue start page of the system. After several seconds, you will enter the main display as follows:

 

1)       When you enter this software display, you can follow the OPERATION manual to start the treatment.

2)       For any emergency situation, please press the emergency button (Red Mushroom) to shut down the laser immediately.

3)       After treatment if you want to turn off the system, you can use the key to shut it down directly. And turn off the air switch at the back panel. You can remove the VAC plug if necessary.

 

 

Operation

Please check with the LCD display. There are totally 6 parameters to be set, including: Laser Power, Pulse Width, Repetition Rate, Skin Cooling Level, Target Energy and Current Energy.

 

1)       The Laser Power shows the peak power of the laser. High laser power means higher pulse energy fluence. For light skin, such as white people and light color asian people, laser power can be adjusted higher for a better performance. Laser Power can be variable from 5%~100%. The step width is 5%. The typical Laser Power for color II skin is 70%~80%.

2)       The Pulse Width shows the length of each laser pulse. A longer pulse width leads to higher pulse energy fluence. Pulse Width can be variable from 5ms~400ms. The step width is 5ms at <100ms, 10ms at 100-300ms, 50ms at 300~950ms. The most popular pulse width is 50~60ms.

3)       The Repetition Rate shows the pulses per second of the laser. A higher repetition rate leads to higher pulse energy fluence. The Repetition Rate can be variable from 1Hz~20Hz with a step width of 1Hz. For scanning operation, the most popular repetition rate is 6~15Hz.

4)       The Fluence at the top-right of the LCD screen shows the laser energy density on the skin. This energy changes according to the 3 parameters of Laser Power, Pulse Width and Repetition Rate.

5)       The Skin Cooling Level shows cooling efficiency of the Sapphire Window and Aluminum Tip of the handle piece. The green block is longer, the cooling is better. It depends on the feeling of the patents. The cooling will be switched off if the green block is all removed. Usually the cooling level is set at 100% level.

6)       The Treatment Assistant is an energy counter for each treatment. The laser energy will be counted till the Treatment Assistant is ‘RESET’. This is a tool for the treatment to remember how many Joules have been treated on the patient.

7)       The middle-left of the LCD is the Laser Head Life Monitor, which shows how many shots have been done for this handle piece. This is calculated as 40J per shot, no matter how many pulses. Please remember this is a standard for warranty.

8)       The bottom-left of the LCD screen shows the system status. There are totally 5 status.

A.       Status: Setting. This means you are setting parameters. Any interruption to adjust the parameter during Ready Status will change the status to ‘Setting’.

B.       Status: Ready. When parameters have been set, press READY button on the bottom-right of the LCD, after 3 seconds, the system will enter ‘Ready’ status. In this status, the pump and fans are working and the laser is ready to use. The skin cooling will also work if already set in this status.

C.      Status: Working. When the handle piece shots laser pulses, the system will enter to ‘Working’ status.

D.      Status: Stand By. When you press ‘Stand By’ button on the bottom-right of the LCD, the system will enter the ‘Stand By’ status. In this status, the pump and fans will stop. The skin cooling will also stop.

E.       Status: Error 01~12. This means the system protections take action. You need to check if anything goes wrong with the system or environment. The error code is as follows:

Error#

Protection

Possible Reasons

Error 01

PT1 and GND open

Need short circuit

Error 02

PT2 and GND open

Need short circuit

Error 03

PT3 and GND open

Need short circuit

Error 04

15° Temperature Protection

N/A

Error 05

35° Temperature Protection

Water temperature >35°C. Please check if the room temperature is >28°C. The room must be with air conditioner. Or it may cause cooling problem for the laser. If this ERROR happens, you need to move it to a room <28°C. Re-start the machine and press ready and do not shoot the laser. The system fan and pump will work for 10 minutes to cool down the water. After the water is cooled down, the ERROR should disappear.

Error 06

45° Temperature Protection

Water temperature >45°C

Error 07

PCB Temperature High

PCB is too high.

Error 08

Flow Rate Protection <2L/min

The water flow for the handle piece is not enough. Check if you bend the tube too much, or the water connection of the handle piece is not well-done. Or there is not enough water in the water tank.

Error 09

Handle Piece Problem

Please contact us to check the handle piece.

Error 10

Over Current Protection

Over current protection for the laser diode. Please check if your wall-plug and VAC voltage is in good conditions. Or contact us for solutions.

Error 11

Laser Diode Temperature

Laser diode temperature is too high.

Error 12

N/A

 

 

9)       Set the parameters (Laser Power, Pulse Width, Repetition Rate, Target Energy / RESET) and press ‘READY’ button to enable the handle piece. For the typical treatment parameters, you can refer to the recommended data or experienced doctor’s advice.

10)   During ‘Ready’ status, you can adjust the skin cooling by yourself, or you can use it at no cooling. You may need to wait for several minutes before the skin cooling tip becomes cold.

11)   Take the handle piece. Pressure the pedal switch or the switch on the handle piece to shot the laser pulses. Keep pressing the button and the laser output will continue. Do not press & release for single pulse.

12)   You can stop the machine anytime by turn off the key in the front panel.

13)   Any sudden situations, press the Emergency Button to stop the laser, and then turn off the key. The Emergency Button is designed to shut off the laser, not shut off the VAC. The Key is designed to shut off the VAC input.

 

Packing List:

Part

Quantity

Note

Laser Machine

1 SET

 

Handle Piece

1 PC

 

Manual

1 PC

Not attached for OEM machines

CE (Electrical Test) Report

1 PC

 

VAC Plug Wire

1 PC

 

Pedal Switch

1 PC

 

Protection Goggles

2 PCS

Not attached for OEM machines

CPC Water Connectors

Several PCS

 

Silicone Soft Tube

1 PC

 

N.W:40KG

G.W:60KG

Sales packaging: Export wooden cases

Packaging size: 63*67*127cm

Shipping & Handling:

  • The date of shipment will be within 5 days after payment.

  • The shipment usually takes 5~7 workdays.

  • The default Shipping:DHL

Payment:

Warranty:

    Please take necessary protections for the operation of the machine and handle piece, and notice that following situations can not be warranted:

    1)       Operation the system without water.

    2)       Power up the system without connecting the handle piece.

    3)       Regular drops of the handle piece.

    4)       Wrong input VAC.

            Other manual operating mistakes.ng mistakes.

           
    Warranty:
    13 months or 5 million times, the first to take

Applications:

Hair Removal

Maintenance:

1.T     1.The water must be checked and changed every 6 months.

2)       2.The machine must be operated in a room with air-conditioner. The room temperature is better <28°C.

3)       3.The environment temperature can not go below ZERO, or the ice may damage the water tanks and water channels  

               inside the machine and the handle piece.

4)       4.Clear the gel on the handle piece and make sure there is no dust attached on the handle piece window.

5)       5.Do not bend the tube of the handle piece too hard, or this may cause flow switch ERROR.

6)       6.Do not plug in & out the handle piece connectors frequently. This may cause bad connections and may cause

              water leakage or not well electrical connections.

 

    7.Do not shot the laser at random targets, or it may cause burning or fire.

 

Photo1:

808-HR-C

Photos2:

808-HR-E

Photo3:

808-HR-F

Photos4:

808-HR-G

 

Photos5:

808-HR-H

Photos6:

808-HR-K

Photos7:

EFFECT

 

 

 

 

 


 

 


 

 If you have this need, please contact me as soon as possible! 


 

If you need 110V,Please give me a message .

Inquiry

(c)2015-2016 openbookalliance.org All Rights Reserved